Tuesday, April 28, 2020

Product and Purification and Infrared spectrum of trimyristin Essay Example

Product and Purification and Infrared spectrum of trimyristin Paper Trimyristin is one member of a class of triglycerides which is found in animals fatty tissues and vegetable or marine oils. It can dissolve in organic compound such as hot acetone readily as it is a non-polar compound.  After the isolation of tirmyristin from nutmeg seed by solvent extraction followed by recrystallizaiton, the present of functional groups in organic molecules can be identified by infrared spectroscopy. Infrared spectroscopy is one of the most useful tools available to the organic chemist as only small quantity of sample is needed, the cost of the spectrometer is relatively small and the application of this method is wide. A molecule is constantly vibrating. Changes in vibrations of a molecule are caused by absorption of infrared light. A particular part of the infrared spectrum is referred to either by its wavelength or its frequency. Therefore, infrared spectrum is a highly characteristic property of an organic compound and can be used both to establish the identity of two compounds and to reveal the structure of a new compound. We will write a custom essay sample on Product and Purification and Infrared spectrum of trimyristin specifically for you for only $16.38 $13.9/page Order now We will write a custom essay sample on Product and Purification and Infrared spectrum of trimyristin specifically for you FOR ONLY $16.38 $13.9/page Hire Writer We will write a custom essay sample on Product and Purification and Infrared spectrum of trimyristin specifically for you FOR ONLY $16.38 $13.9/page Hire Writer Small amount of activated carbon is added to during the recrystallization in order to absorb the colour inside the solution. After that, it can be filter out by the fluted filter paper.  Objective:  To isolate trimyristin from nutmeg seed by solvent extraction  To purified it by recrystallization.  To obtain an infrared spectrum of the isolated trimyristin from the recrystallized trimyristin from the experiment.  To study the difference between the infrared spectrum results of the isolated trimyristin from experiment 3 and the recrystallized trimyristin  Materials and Methods  Procedure for the isolation trimyristin from nutmeg seed by solvent extraction. 15.13g of ground nutmeg seed, 40ml of acetone and five antibumping granules were placed into a 100ml round bottom flask. The ground glass joints of the 100-ml reaction flask and the outer joint of the reflux condenser were lubricated by Vaseline to prevent the glass joints from freezing together. The mixture was then allowed to reflux for 15 minutes.  Then, the heating mantle was switched off and the hot solution was filtered into a 100 ml conical flask containing 15 ml acetone on a hot water bath using a hot stemless funnel which was preheated to about 80?C and fitted with a fluted filter paper. The extracts were allowed to cool in an ice bath until crystallization was complete while the solid material was isolated by suction filtration. Procedure for recrystallization  The isolated product from ex 3 was placed in a 100ml conical flask. Then 30ml acetone and a very small amount of activated charcoal were added. The mixture was warmed in a hot water bath. After that, the solution was filtered and allowed to cool in an ice bath. The purified trimyristin crystals were collected by suction filtration. The weight and melting point of the product were also determined.  Procedure for infrared spectroscopy. About 15 to 20 mg of the recrystallized sample was ground in an agate mortar, then a drop of the paraffin oil was added, and was ground for 2 to 5 minutes until a mull was formed. The mull was transferred to the bottom salt plate of a demountable cell. The top plate was then placed and twisted to distribute the sample evenly and eliminate all air pockets and the spectrum was run. After running the sample, the salt plates were wiped clean with a tissue paper saturated with acetone. The apparatus for refluxing a solution is always left open to the atmosphere during heating and is never stoppered because if the apparatus is in a closed system and the temperature of that system is increased, air will expand. And the solvent will evaporate into gas so the pressure inside will increase also. As the pressure inside will continue to increase and until the apparatus cannot stand the pressure, the apparatus will break and the solution may spread. That is why it is really unsafe when heating in a closed system. IR spectrum  In our group, the IR spectrum of recrystallized sample was done. In the spectrum, there were a peak at 1735.84cm-1 which indicated the presence of C=O bond,  peaks at about 1180cm-1 which indicated the presence of C-O bond and the peak at 2842.67cm-1 to 2920cm-1 indicated the presence of aliphatic C-H bond.  By comparing the IR spectrum of un-recrystallized sample from the other group, similar pattern of the spectrum was obtained. Same functional groups were found in that sample but the transmittance of the recrystallized one was much lower than the un-recrystallized one which indicated that the purity of the recrystallized sample was higher. Source of errors  If the mixture was heating under reflux for too long, other things may also extract. Moreover, there was loss of sample during the transfer process as some solid might adhere on the flasks, Buchner funnel or even the weighting bottle. Some of the trimyristin might not completely dissolve in the hot acetone so less trimyristin was extracted. As the solubility of trimyristin in hot acetone is much bigger than in colder acetone, if we dont filter quickly after heating, the temperature would decrease and less trimyristin would be isolated. For the IR spectrum of the recrystallized sample, some sharp unnecessary peaks may appear because of the acetone or other impurities as we used acetone to clean the plate which did not evaporate completely before we put them in the spectroscopy. Improvement  For the purity, we can repeat the process of recrystallization although the yield might be lowered. Moreover, the product could be allowed to dry in the suction filter for more time. Tiny amount of charcoal was added first, then warm the mixture for a while if the yellow colour still present, a little more charcoal is added instead of adding too much at first. For the reflux, it is better not reflux for more than 20 minutes. During reflux, the stand should shake gently so that the trimyristin can better dissolve in the hot acetone and should filter the solution as quick as possible after heating. Finally, wait for a while after cleaning the salts plates or apparatus used for IR spectroscopy so that the acetone can fully evaporate in order not to interfere the results.

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.